Configuration of the camera
STINGRAY Technical Manual V2.2.0
290
Advanced register: trigger counter
The trigger counter feature is controlled by the following advanced feature
register:
Having this feature enabled, the current trigger counter value (external trig-
ger seen by hardware) will be inserted as a 32-bit integer value into any cap-
tured image.
Setting the Reset flag to 1 resets the trigger counter to 0: the Reset flag is
self-cleared.
The ON_OFF and LinePos fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.
Additionally there is a register for direct read out of the trigger counter
value.
Register Name Field Bit Description
0xF1000620 TRIGGER_COUNTER Presence_Inq [0] Indicates presence of this feature
(read only)
Reset [1] Reset trigger counter
--- [2..31] Reserved
0xF1000624 TRGCNT TriggerCounter [0..31] Trigger counter
Table 148: Advanced register: Trigger counter
Note
L
The 4 bytes of the trigger counter value will be inserted as
the 9th to 12th byte of a line.