Controlling image capture
STINGRAY Technical Manual V2.2.0
171
In this case the camera can resynchronize the horizontal clock to the new
trigger event, leaving only a very short uncertainty time of the master clock
period.
Model Exposure start jitter
(while FVal)
Exposure start jitter
(while camera idle)
Stingray F-033 ± 9.75 µs ± 1.30 µs
Stingray F-046 ± 11.59 µs ± 1.30 µs
Stingray F-080 ± 15.29 µs ± 3.33 µs
Stingray F-145 ± 23.20 µs ± 5.40 µs
Stingray F-146 ± 23.20 µs ± 5.87 µs
Stingray F-201 ± 22.61 µs ± 3.56 µs
Table 65: Jitter at exposure start (no binning, no sub-sampling)
Note
L
Jitter at the beginning of an exposure has no effect on
the length of exposure, i.e. it is always constant.