Camera interfaces
PIKE Technical Manual V4.0.0
94
Triggers
All inputs configured as triggers are linked by AND. If several inputs are being
used as triggers, a high signal must be present on all inputs in order to gen-
erate a trigger signal. Each signal can be inverted. The camera must be set
to external triggering to trigger image capture by the trigger signal.
Figure 46: Input block diagram
Figure 47: Input Ground (InGND) (Pin no. 7 from camera I/O connector)
In1 – Pin 4
390R
390R
In2 – Pin 11
InGND – Pin 7